Los Bronces Slurry Pipeline
Client
Anglo American Sur
Location
Santiago, Chile
Scope
Development of the Basic and Detailed Engineering for the replacement of the slurry pipeline.
Technical Data
- Transport capacity: 54 KTPD
- Length: 56 km
- Elevation change: from 3,400 to 740 m above sea level
- Material: Bare API 5L X65 steel
- Diameter: 24”
- 5 pressure-dissipation stations, classes #600 to #1,500